mallbrazerzkidai.blogg.se

Elk m1 ethernet module activetcl
Elk m1 ethernet module activetcl




elk m1 ethernet module activetcl

The complete list of trouble statuses are: Was an AC failure then system_trouble_status would be the string System_trouble_status would be “Lost Transmitter zone 42”. If the trouble is for a zone then zone is appended to the trouble name.įor example, if zone 42 wireless sensor lost communication with the panel then Only active trouble statuses are in the list. The format of the system_trouble_status attribute is a comma separated list Panel sensor (often named sensor.elkm1) in Home Assistant. Reported using the system_trouble_status attribute of the The ElkM1 is able to report general system trouble statuses. If you are wishing to track keypresses on ElkM1 keypad or if you are wishing to track the armed, disarmed, and alarm state of the ElkM1 then this option should be set. Oddly, this option tracks keypad changes and alarm status. If you are using ElkM1 Lights this allows Home Assistant to track the status of the lights. If you are using ElkM1 Tasks this allows Home Assistant to track the status of the Tasks. If you are using Outputs this allows Home Assistant to track the status of the Outputs. If you are using Zones this allows Home Assistant to track the status of the Zones. If you are using the features below then these respective global options Note that without Global Setting 35 set and in a single area system,Ĭhanged_by and changed_by_id are updated when a user enters a validĬode on a physical keypad. On the ElkM1 panel Global Setting 35, “Transmit Event Log” must be The alarm_control_panel hold those two attributes. The changed_by and changed_by_id attributes of The ElkM1 integration tracks the user number and name of the last user name toĪrm or disarm the panel. Version of the TLS protocol, the user must specify the TLS version to connect. Note that ELK-M1XEP does not support auto-negotiation of the When adding the ElkM1 integration in the user interface use secure for TLS 1.0 and In secure mode the version of the ELK-M1XEP determines which secure protocol is supported.ĮLK-M1XEP versions less than 2.0.46 support TLS 1.0, while version 2.0.46 and above support The ELK-M1XEP is the Ethernet controller board for the ElkM1.

#Elk m1 ethernet module activetcl manual

Check the “ElkM1 RS232 Protocol” manual for details. Many features will work with lower versions of the ElkM1. ElkM1 Versionįorce arm away and stay are available in 5.3.0 or higher. In order for the ElkM1 integration to work to its fullest with Home Assistant theĮlkM1 panel must be configured correctly. This document can be found on the Internet. The implementation follows the Elk Products ElkM1 “ASCII Protocol & Interface

  • Switch - ElkM1 outputs are represented as switch entities.
  • Sensor - ElkM1 counters, keypads, panel, settings, and zones are represented as sensor entities.
  • Scene - ElkM1 tasks are represented as scene entities.
  • Light - An ElkM1 light (which can be X10, Insteon, UPB) is represented as a light.
  • Climate - An ElkM1 thermostat is represented as a climate entity.
  • Normal is off and any of the other values is on.

    elk m1 ethernet module activetcl elk m1 ethernet module activetcl

  • Binary Sensor - ElkM1 zones that have 4 states (i.e.: are not analog zones) are represented as binary_sensor entities.
  • Alarm - An ElkM1 area (also known as partition) is represented as an alarm_control_panel.
  • There is currently support for the following device types within Home Assistant: The Elk-M1 controller is manufactured by Elk Products. The Elk-M1 is a home security and automation controller that is capable of alarm control panel functions and automation.






    Elk m1 ethernet module activetcl